High and low temperature damp-heat chamber dedicated for Vehicles
The refrigeration system must meet the following requirements: one 5-tonne or two 2.5-tonne vehicles with a total engine displacement of 4.0T and a maximum power of 300KW to start at -18 ℃ in the chamber, and keep the Cabin temperature stable while maintaining 50% rated engine rpm. Effective internal dimension: 10m x 5m x 4m (D*W*H)
Temperature range: -45 ~ 90 ℃;
Temperature fluctuation: ≤ ± 0.5 ℃;
Temperature uniformity: ≤ 2 ℃
Humidity range: 20% ~ 98% RH;
Humidity deviation: ± 5%