environmental test chamber for vehicle performance
Main technical data:
Specifications
Internal dimension: 163000 × 8300 × 5200 mm (L × W × H).
Heat exchanger height (lower): ≥3500mm
Floor insulation: 150mm PU material
Chamber flooring: stainless steel plate pattern, solid layer thickness ≥ 3mm, thickness of convex part of the pattern 2mm.
Floor load bearing: surface load 1200kg/wheel, simultaneously meet the shaft load ≥ 2000kg
Interface between Floor and pit edge: to be designed, supplied and installed by Hance Tech.
Chassis dynamometer supporting block: insulated, designed to meet the chassis dynamometer weight requirements.
Vehicle access: 1, net dimension 3000 x 3000mm (width x height), two doors open opposite, with a 300 mm x 300 mm (W x H) viewing window on each door, can be opened from the inside, when locked or heating glass.
Personnel access: for 1 person entry and exit, net size 900 mm x 1900 mm, with heating frame. With a 300 mm x 300 mm viewing window, heated burst-proof glass. In any case, the door can be opened from the inside.
pit construction for Chassis dynamometer: buyer will be responsible for the pit construction and site excavation for the environment test chamber
control room observation window: two as the case may be, 2000 x 1000 mm (width x height) with hermetic, thermal insulation, acoustic insulation, surface-heat defrosting features.
Lighting: dedicated lighting (500lux or above), suitable for the entire temperature range of the environmental chamber, an emergency lighting (including power supply), can work continuously for over 1 hour in the ambience of -40℃
Socket: 4pcs, 220VAC/10A, 2pcs 220VAC/16A, 2pcs 380VAC/32A, each 220VAC socket should be equipped with a triangular adaptor of the Chinese standard.
Cable wiring holes: 4 sets, each Ø100mm, are available for a variety of diameters, a lead hole can seal up to 16 cables
Personnel transition room: for 1 person entry, 1500 x 1500 x 2100 mm (LxWxH), personnel access door net size 900 x 1900 mm (W x H). Open from the inside, can be locked from the outside
Cabin pressure: pressure balance valve installed, under any circumstances to maintain the environment within the cabin for the 0 ~ 50Pa range of micropositive pressure.