中文   |   English   Hance Technologies Limited           Tel:  021-57863847
thermal shock - small

thermal shock - small

 
Thermal shock test chamber - small 

The equipment is an integrated structure, consisting of: main chamber body, air circulation part, refrigeration part, control system and pneumatic, air damper.
1. the sample quickly placed into the sample area, through the air damper conversion temperature in the pre-cooled low-temperature room or preheated high temperature room is quickly transmitted to the test area;
2. compact structure, small footprint;
3. the test chamber can be used for thermal shock test chamber or separately be used as a high and low temperature test chamber.
4. when the UUT is completely stationary, especially suitable for static testing.
 
Features:
 
1. thermal shock range: -55 ~ +150℃ 
2. high temperature chamber temperature range: 60 ~ +210℃
3. low temperature chamber temperature range: -10℃ ~ -75℃
4. low temperature chamber cooling time: ≤ 75min, from -10℃ ~ -75℃;
5. high temperature chamber heating time: ≤ 30min, from +60℃ ~ +200℃
6. temperature deviation: ≤ ±2℃ (constant state)
7. temperature fluctuation: ≤ ±0.5℃ (constant state)
8. temperature uniformity: ≤ 2 ℃ (constant state)
9. shock test chamber temperature recovery time: ≤5min (150℃ ~ -55℃)
10. pneumatic damper switch mode
11. temperature conversion time: ≤ 10s 
 


 
 

Links:   

Tel:021-57863847     E-mail: sales@hance-tech.com

Add:Yuxiu Rd 136, Songjiang, 201699 Shanghai

Hance Technologies Ltd, based in Shanghai, with an area of more than 3,500 sqm of proprietary facility, show room and office floor on the premises covering an area about 7000 sqm, with representative offices in major Chinese cities such as Hongkong, Canton, Peking, Chungking and Wuhan etc., is a comp...